from Original price$349.99$269.99-$499.98CSM ( RE4040-BLR ) 1900 GPD BW-LE Brackish 4"x40" Water Replacement Reverse Osmosis Membrane
CSMRE4040-BLRLow pressure grade RO element with extended area for brackish water The RE4040-BLR commercial RO membrane is designed to filter brackish water under low water pressure conditions. Operating under low water pressures compared to other RO membranes will reduce energy costs while maintaining high performance rates. Specifications : Flow Rate: 1,900 Gallons Per Day Dimensions: : 40" X 4" Replace every 24 months Thin Film Membrane (TFM)Save up to 11% - $25.98-$49.96
CSM RE1812-24 Thin Film Composite Replacement Residential Reverse Osmosis Membrane
CSMRE1812-24The CSM Reverse Osmosis Membranes fits in a standard membrane housing for most conventional reverse osmosis systems. RANGE : 24 GALLONS PER DAY The same standard membrane housing can accommodate RO membranes with capacities ranging between 18-180 gallons per day (GPD). Specifications are based on 500 mg/L NaCl solution at 60 psi net pressure (4.1 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%. There is a wide range of inorganic compounds that can be removed from drinking water with this reverse osmosis membrane. If you would like to change your membrane to a capacity other than what was originally in your Reverse Osmosis System, we recommend changing the drain flow control also. Flow restrictors help maintain the correct drainage for the membrane to prevent premature fouling/clogging of the membrane. - $26.25-$50.96
CSM RE1812-35 Thin Film Composite Replacement Residential Reverse Osmosis Membrane
CSMRE1812-35The CSM Reverse Osmosis Membranes fits in a standard membrane housing for most conventional reverse osmosis systems. RANGE : 35 GALLONS PER DAY The same standard membrane housing can accommodate RO membranes with capacities ranging between 18-180 gallons per day (GPD). Specifications are based on 500 mg/L NaCl solution at 60 psi net pressure (4.1 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%. There is a wide range of inorganic compounds that can be removed from drinking water with this reverse osmosis membrane. If you would like to change your membrane to a capacity other than what was originally in your Reverse Osmosis System, we recommend changing the drain flow control also. Flow restrictors help maintain the correct drainage for the membrane to prevent premature fouling/clogging of the membrane. - $29.99-$53.98
CSM RE1812-50 Thin Film Composite Replacement Residential Reverse Osmosis Membrane
CSMRE1812-50The CSM Reverse Osmosis Membranes fits in a standard membrane housing for most conventional reverse osmosis systems. RANGE: 50 GALLONS PER DAY The same standard membrane housing can accommodate RO membranes with capacities ranging between 18-180 gallons per day (GPD). Specifications are based on 500 mg/L NaCl solution at 60 psi net pressure (4.1 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%. There is a wide range of inorganic compounds that can be removed from drinking water with this reverse osmosis membrane. If you would like to change your membrane to a capacity other than what was originally in your Reverse Osmosis System, we recommend changing the drain flow control also. Flow restrictors help maintain the correct drainage for the membrane to prevent premature fouling/clogging of the membrane. - $33.99-$63.98
CSM RE1812-60 Thin Film Composite Replacement Residential Reverse Osmosis Membrane
CSMRE1812-60The CSM Reverse Osmosis Membranes fits in a standard membrane housing for most conventional reverse osmosis systems. RANGE : 60 GALLONS PER DAY The same standard membrane housing can accommodate RO membranes with capacities ranging between 18-180 gallons per day (GPD). Specifications are based on 500 mg/L NaCl solution at 60 psi net pressure (4.1 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%. There is a wide range of inorganic compounds that can be removed from drinking water with this reverse osmosis membrane. If you would like to change your membrane to a capacity other than what was originally in your Reverse Osmosis System, we recommend changing the drain flow control also. Flow restrictors help maintain the correct drainage for the membrane to prevent premature fouling/clogging of the membrane. - $37.99-$69.99
CSM RE1812-80 Thin Film Composite Replacement Residential Reverse Osmosis Membranes
CSMRE1812-80The CSM Reverse Osmosis Membranes fits in a standard membrane housing for most conventional reverse osmosis systems. RANGE : 80 GALLONS PER DAY The same standard membrane housing can accommodate RO membranes with capacities ranging between 18-180 gallons per day (GPD). Specifications are based on 500 mg/L NaCl solution at 60 psi net pressure (4.1 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%. There is a wide range of inorganic compounds that can be removed from drinking water with this reverse osmosis membrane. If you would like to change your membrane to a capacity other than what was originally in your Reverse Osmosis System, we recommend changing the drain flow control also. Flow restrictors help maintain the correct drainage for the membrane to prevent premature fouling/clogging of the membrane. - $38.99-$69.99
CSM RE2012-100 Thin Film Composite Membrane 100GPD
CSMRE2012-100CSM RE2012-100 Thin Film Composite Membrane 100GPD This Standard Size Reverse Osmosis Membrane fits in a standard membrane housing like the one shown on this RO unit. RANGE : 100 GALLON PER DAY The same standard membrane housing can accommodate RO membranes with capacities ranging between 18-100 gallons per day (GPD). Specifications are based on 500 mg/L NaCl solution at 60 psi net pressure (4.1 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%. There is a wide range of inorganic compounds that can be removed from drinking water with this reverse osmosis membrane. If you would like to change your membrane to a capacity other than what was originally in your Reverse Osmosis System, you must change the drain flow control also. The membrane and drain flow restrictor are sized to go together. We have a variety of drain flow restrictors available. -
Save up to 11%
from Original price$49.99$39.99-$69.99CSM RE2012-LP Reverse Osmosis Membrane 50 GPD at low flow
CSMRE2012-LPCSM RE2012-LP Reverse Osmosis Membrane 50 GPD 1 CSM Membrane RE-2012-LP 2.0" X 12" LOW PRESSURE MEMBRANE CSM membranes can eliminate substances larger than 0.0001um, such as carcinogens, THMs, heavy metal ions, bacteria and viruses in water. Perfect for tap water applications. This special low pressure membrane provides 50 GPD a low pressure at only 20 PSI. It is ideal for low water pressure applications. The same standard membrane housing can accommodate RO membranes with capacities ranging between 18-100 gallons per day (GPD). Average NaCl Rejection: 90% Permeate Flow at 20 PSI: 60 GPD Specifications are based on 250 mg/L NaCl solution at 20 psi net pressure (1.37 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%. RANGE : 50 GALLONS PER DAY * Model Number: RE2012-LP * Membrane Type: Polyamide Thin-Film Composite * Maximum Operating Temperature: 113°F (45°C) * Maximum Operating Pressure: 125 psi (0.86MPa) * Maximum Feed Flow Rate: 2.0 gpm (M3/hr) * Ph Range, Continuous Operation: 2.0 ~ 11.0 * Maximum Feed Silt Density Index: <5 * Free Chlorine Tolerance: * Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, we recommend removing residual free chlorine by pretreatment prior to membrane exposure.Save up to 11% -
Save up to 11%
from Original price$49.99$39.99-$69.99CSM RE2012-LPF Reverse Osmosis Membrane150 GPD at low flow
CSMRE2012-LPFCSM RE2012-LPF Reverse Osmosis Membrane150GPD 1 CSM Membrane RE-2012-LPF 2.0" X 12" LOW PRESSURE MEMBRANE CSM membranes can eliminate substances larger than 0.0001um, such as carcinogens, THMs, heavy metal ions, bacteria and viruses in water. Perfect for tap water applications. This special low pressure membrane provides 60 GPD a low pressure at only 20 PSI. It is ideal for low water pressure applications. The same standard membrane housing can accommodate RO membranes with capacities ranging between 18-100 gallons per day (GPD). Average NaCl Rejection: 90% Permeate Flow at 20 PSI: 60 GPD Specifications are based on 250 mg/L NaCl solution at 20 psi net pressure (1.37 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%. RANGE : 150 GALLONS PER DAY * Model Number: RE2012-LPF * Membrane Type: Polyamide Thin-Film Composite * Maximum Operating Temperature: 113°F (45°C) * Maximum Operating Pressure: 125 psi (0.86MPa) * Maximum Feed Flow Rate: 2.0 gpm (M3/hr) * Ph Range, Continuous Operation: 2.0 ~ 11.0 * Maximum Feed Silt Density Index: <5 * Free Chlorine Tolerance: * Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, we recommend removing residual free chlorine by pretreatment prior to membrane exposure.Save up to 11% -
Save up to 10%
from Original price$349.99$289.99-$538.99CSM RE4040-BE - 4"x40"; 2400 GPD Brackish Water Replacement Reverse Osmosis Membrane
CSMRE4040-BEFlow Rate: 2,400 Gallons Per Day Dimensions: 40" X 4" Replace every 24 months Thin Film Membrane (TFM) NSF CertifiedSave up to 10% -
Save up to 11%
from Original price$349.80$269.99-$519.98CSM RE4040-BLN - 4"x40"; 2600 GPD TW-LE Energy Replacement Reverse Osmosis Membrane
CSMRE4040-BLNLow Pressure Grade RO Element for Tap or Brackish The RE4040-BLN commercial RO membrane is designed to filter brackish water under low water pressure conditions. Operating under low water pressures compared to other RO membranes will reduce energy costs while maintaining high performance rates. Specifications Flow Rate: 2,600 Gallons Per Day Dimensions: : 40" X 4" Replace every 24 months Thin Film Membrane (TFM) Product Flow @ 150 PSISave up to 11%